About Us

Products Approvals

Product Approvals have a number of very useful benefits. They are used to pull permits, they provide the engineering and test data that you will use when installing to insure a proper and complete installation. Just about any question you have regarding a product can be answered using the Product Approval.

Products that have a Florida Product Approval can be found on the Florida Building Web Site: http://www.floridabuilding.org
Products that have a Miami-Dade Product Approval can be found on the Miami-Dade Goverment Web Site: http://www.miamidade.gov

For your convenience we have listed each of our hurricane protection products here with a link directly to their product approval and evaluation report.

 

GPP Fabric Shutters - Series 2000 - FL#15088.1

Fabric made from high density Fabric made from high density polyethylene tapes, coated on 2 sides with low density polyethylene and laminated together with 3 layers of low density polyethylene.

Limits of Use

Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: N/A
Other: Large Missile Impact resistant with a Maximum span of 12'-7" @ 60 p.s.f. See sheet 13 of installation drawings for type and substrate permissible with maximum span as well as other spans and pressures, based on mounting types and substrates.

Installation Instructions

 FL15088 R0 II GLOBAL PROTECTION PRODUCTS 11-212 - Click to Download
Verified By: Walter A. Tillit Jr. PE-44167
Created by Independent Third Party: Yes

Evaluation Reports

FL15088 R0 AE GLOBAL PROTECTION PRODUCTS 11-212 - Click to Download
Created by Independent Third Party: Yes

 

 

GPP 20 ga Corrugated Galvanized Steel Storm Panel - FL#15076.1

20 Gage Galvanized Steel Storm Panels/HVHZ

Limits of Use

Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: N/A
Other: Large missile impact resistant with Maximum span of 12'-4" for + or -43.8 p.s.f. ASD Design load for regular panels (see sheet 8 & 10). Maximum span is 8'-8" for life safety panel and 5'-10" for E-Z hung panels.

Installation Instructions

FL15076 R0 II GLOBAL PROTECTION PRODUCTS 11-213 - Click to Download
Verified By: Walter A. Tillit Jr. PE-44167
Created by Independent Third Party: Yes

Evaluation Reports

FL15076 R0 AE GLOBAL PROTECTION PRODUCTS 11-213.pdf - Click to Download
Created by Independent Third Party: Yes

 

 

GPP 24 ga Corrugated Galvanized Steel Storm Panel - FL#15076.2

24 Gage Galvanized Steel Storm Panels/NHVHZ

Limits of Use

Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: N/A
Other: Large missile impact resistant with Maximum span of 12'-0" for + or -20 p.s.f. ASD Design load and 13'-0" for + or - 20 p.s.f. ASD Design load for regular panels mounted without "h" header respectively. See sheets 3, 12 & 17 of installation drawings for other spans and pressures.

Installation Instructions

FL15076 R0 II GLOBAL PROTECTION PRODUCTS 11-214 - Click to Download
Verified By: Walter A. Tillit Jr. PE-44167
Created by Independent Third Party: Yes

Evaluation Reports

FL15076 R0 AE GLOBAL PROTECTION PRODUCTS 11-214 - Click to Download
Created by Independent Third Party: Yes

 

 

GPP 0.039" (min.) Corrugated Galvanized Steel Storm Panel - NOA#08-0611.02

20 gauge Galvanized Steel Storm Panel Shutter

Notice of Acceptance

Miami-Dade NOA#08-0611.02 - Click to Download
Verified By: Walter A. Tillit Jr. PE-44167
Created by Independent Third Party: Yes

 

 

GSS-1 Genesis Shutter System - FL#15549

Aluminum Accordion Shutter

Notice of Acceptance

Florida #15549 - Click to Download | Certificate of Competency
Verified By: MCY Enfineering, Inc.
Created by Independent Third Party: Yes
* Global Protection Products, LLC (DBA Atrium Windows & Doors)