Products ApprovalsProduct Approvals have a number of very useful benefits. They are used to pull permits, they provide the engineering and test data that you will use when installing to insure a proper and complete installation. Just about any question you have regarding a product can be answered using the Product Approval. Products that have a Florida Product Approval can be found on the Florida Building Web Site:
http://www.floridabuilding.org For your convenience we have listed each of our hurricane protection products here with a link directly to their product approval and evaluation report.
GPP Fabric Shutters - Series 2000 - FL#15088.1Fabric made from high density Fabric made from high density polyethylene tapes, coated on 2 sides with low density polyethylene and laminated together with 3 layers of low density polyethylene. Limits of UseApproved for use in HVHZ: NoApproved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: Large Missile Impact resistant with a Maximum span of 12'-7" @ 60 p.s.f. See sheet 13 of installation drawings for type and substrate permissible with maximum span as well as other spans and pressures, based on mounting types and substrates. Installation InstructionsFL15088 R0 II GLOBAL PROTECTION PRODUCTS 11-212 - Click to DownloadVerified By: Walter A. Tillit Jr. PE-44167 Created by Independent Third Party: Yes Evaluation ReportsFL15088 R0 AE GLOBAL PROTECTION PRODUCTS 11-212 - Click to DownloadCreated by Independent Third Party: Yes
GPP 20 ga Corrugated Galvanized Steel Storm Panel - FL#15076.120 Gage Galvanized Steel Storm Panels/HVHZ Limits of UseApproved for use in HVHZ: YesApproved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: Large missile impact resistant with Maximum span of 12'-4" for + or -43.8 p.s.f. ASD Design load for regular panels (see sheet 8 & 10). Maximum span is 8'-8" for life safety panel and 5'-10" for E-Z hung panels. Installation InstructionsFL15076 R0 II GLOBAL PROTECTION PRODUCTS 11-213 - Click to DownloadVerified By: Walter A. Tillit Jr. PE-44167 Created by Independent Third Party: Yes Evaluation ReportsFL15076 R0 AE GLOBAL PROTECTION PRODUCTS 11-213.pdf - Click to DownloadCreated by Independent Third Party: Yes
GPP 24 ga Corrugated Galvanized Steel Storm Panel - FL#15076.224 Gage Galvanized Steel Storm Panels/NHVHZ Limits of UseApproved for use in HVHZ: NoApproved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: Large missile impact resistant with Maximum span of 12'-0" for + or -20 p.s.f. ASD Design load and 13'-0" for + or - 20 p.s.f. ASD Design load for regular panels mounted without "h" header respectively. See sheets 3, 12 & 17 of installation drawings for other spans and pressures. Installation InstructionsFL15076 R0 II GLOBAL PROTECTION PRODUCTS 11-214 - Click to DownloadVerified By: Walter A. Tillit Jr. PE-44167 Created by Independent Third Party: Yes Evaluation ReportsFL15076 R0 AE GLOBAL PROTECTION PRODUCTS 11-214 - Click to DownloadCreated by Independent Third Party: Yes
GPP 0.039" (min.) Corrugated Galvanized Steel Storm Panel - NOA#08-0611.0220 gauge Galvanized Steel Storm Panel Shutter Notice of AcceptanceMiami-Dade NOA#08-0611.02 - Click to DownloadVerified By: Walter A. Tillit Jr. PE-44167 Created by Independent Third Party: Yes
GSS-1 Genesis Shutter System - FL#15549Aluminum Accordion Shutter Notice of AcceptanceFlorida #15549 - Click to Download | Certificate of CompetencyVerified By: MCY Enfineering, Inc. Created by Independent Third Party: Yes * Global Protection Products, LLC (DBA Atrium Windows & Doors) |